› About SGT
› Our Products
› Workshops/Training
› Photo Gallery
› Testimonials
› Tutorials
› Newsletters
› Technical Documents
› Featured Articles
› Distributors
› Sitemap
› Contact Us
› Home
|

Tek Gel™ for Flattooing™
› View Flyer (PDF)
› TDS - Technical Data Sheet (PDF)
› MSDS - Material Data Safety Sheet (PDF)

 |
 |
Introducing the FLATTOO™ PROCESS
"Tattooing" designs into flat concrete surfaces
Product code numbers:
TGS201 (1-gallon)
TGS205 (5-gallon)
TGS255 (55-gallon drum)
Flattoo™ Certification Classes Held Monthly
Specifically developed to work with vinyl FLATTOOS™ |
Advantages
Precision Flattooing™
Works with vinyl Flattoo™ material
Saves time, labor & equipment costs
One-step controlled application
Increases creativity
Flat, vertical & inverted surfaces
Ready to use - Do not dilute
Fast 5 - 30 minutes
Indoor/Outdoor & small/large jobs
Environmentally & end user safer
Lower fuming
Easily contained
Easily neutralized - flush to sewer
Distributor Inquires Welcomed
PRODUCT DESCRIPTION: TEK GEL™ for Flattooing
Precision Decorative Concrete Stenciling
|
Gelled Acid Formula: | Hydrochloric (HCl) 18-25% |
|
Color: | Opaque gel |
|
Odor: | pungent |
|
pH: | +/- 1 |
|
Solubility: | Infinite in water |
|
Flammability: | Non-flammable |
|
Flash Point: | > 200˚C |
|
Freeze/Thaw: | Store between 38˚F & 100˚F |
|
Coverage: | 200 - 400 sq. ft. /gal. |
|
Storage: | Stable under normal conditions. Do not store near or mix with strong alkalis, i.e., sodium or potassium |
|
User Warning: | Use in well ventilated areas only |
|
Safety Wear: | Splash goggles. Ventilator and neoprene gloves recommended. Avoid excessive direct contact with skin |
|
Health rating: | 3 Severe (Corrosive) |
DIRECTIONS FOR USE / APPLICATION:
- Ready to use, DO NOT DILUTE
- Surface must be clean, free of grease/oil & dry
- Shake or stir contents well before applying
- Apply stencil according to manufacturer's recommendations
- Apply product using a non-metallic, acid resistant brush. For best results and clarity, avoid disturbing the bond of the stencil to the concrete surface
- Allow product to sit on surface 5 Ð 30 minutes Leave stencil in place
- Carefully collect excess product into a pail using plastic trowel. Neutralize before discharging to sewer.
- Thoroughly neutralize and rinse entire stenciled area with water. A second clean water rinse is required. Re-check stencil adhesion prior to adding colors, i.e., liquid color hardeners
- Remove stencil & allow surface to dry before sealing
PRIMARY USE:
Product can be pumped from container by using an acid resistant hand pump.
Product must be stirred or mixed well before use, with or without a pump.
- Works with vinyl stencil materials for precision decorative stenciling.
- Produces a uniform etched surface for improved subsequent product adhesion
- Can be used on new or old concrete surfaces
LIMITATIONS/INCOMPATIBILITIES:
- Avoid strong oxidizers, caustics, fabrics, carpets
- Avoid contact with metals and marble
- Caution: If product comes in contact with metals, flush immediately with water to avoid damage.
- If used indoors, provide adequate ventilation
- Humidity increases the need for additional ventilation
- Excessive heat can cause evolution of gaseous hydrogen-chloride
- Avoid continuous direct sunlight
- Avoid freezing
- Do not reuse container.
- Follow all applicable Local, State, and Federal chemical disposal regulations
TOP 20 ADVANTAGES of TEK GEL™ for Profiling
- Ready to use; DO NOT DILUTE
- Saves time & labor
- Gelled consistency permits longer contact time
- Can be applied to flat, vertical & inverted surfaces
- Works with vinyl stencil materials
- Increases creativity and precision stenciling
- Increases bondability of subsequent treatments
- Improves warranty on subsequent products
- Non-abrasive
- Can utilize in-house craftsman, short training time
- Job site flexibility
- Safer for environment & end-user
- Low fuming, Non-flammable
- Can be used on new & old concrete
- Can be used on large & small job sites
- Removes algae, mineral build-ups, rust, etc.
- Rinses with water
- Neutralizes with water
- Flush to sewer
- Excellent shelf life
ORDERING INFORMATION:
Packaging: 1, 5
Weight per gallon: 9.6 lb
DOT: NMFC 44155
IATA: UN1789, Hydrochloric Acid, 8, PGII
PERFORMANCE TIPS:
- Test patch before use is recommended
- Not intended to etch through epoxy coatings or for use on metals.
- Average coverage 300 sq. ft. per gallon. Coverage rates vary with surface of concrete
WARRANTY SUMMARY:
For complete warranty statement and important limitations, read the MSDS and Warranty Sheet. Generally, Surface Gel Tek, LLC represents and warrants only that its products are of consistent quality. No other oral or written statement is authorized. Any liability is limited to refund or replacement of defective product. The end user shall determine product's suitability and assume all risks and liability.
MANUFACTURE INFORMATION:
Surface Gel Tek, LLC
663 W. 2nd Ave., #15
Mesa, AZ 85210
T: 480-970-4580
TF: 888-872-7759
F: 480-421-6322
Website: www.surfacegeltek.com
Email: info@surfacegeltek.com
Sold Direct and through Distributors
› Return to Products Menu

|